Chimney Cap
The small cap that keeps rain, animals, and embers out — fitted while we're up there.
Learn moreOlder chimneys love to throw curveballs — offsets, bends, odd cross-sections — and that's exactly where a flexible stainless liner earns its place: 316Ti for solid fuel, 304 for gas, threaded through where a rigid liner simply won't pass. It's UL-1777 listed and carries a lifetime warranty. We plan it as a clean single-day install and coordinate it with any cap or crown work at the top, so the whole flue gets brought current in one tidy visit by one crew.
This page is about a material choice, not a separate service: when a flue needs a liner, should it be the flexible corrugated stainless tube or a rigid one? Flexible wins exactly when the geometry defeats rigid pipe — a chimney with an offset or 'dogleg,' an elbow at the smoke chamber, an out-of-round or shouldered clay tile, or a tight throat a stiff length can't be fed through. The corrugation lets the liner bend around the bends and compress through the pinch points while still sealing as one continuous channel. How it differs from the general relining page: relining is the decision to replace a failed liner and can end in flexible, rigid, or cast-in-place, while this page is specifically the flexible option, chosen on geometry and appliance, whether the flue is being relined or lined for the first time.
Choosing flexible is a measurement before it's a purchase. We camera-scope the flue and map every offset, elbow, and dimensional pinch, then decide whether flexible is genuinely required (rigid won't pass) or simply preferred. Where rigid would pass a straight, accessible flue, we say so — rigid liner has smoother walls and marginally better draft, so we don't sell flexible by default. Where the throat is tight, we run an oval-profile flexible liner of equal cross-sectional area so it passes where a round one won't. The alloy still tracks the fuel — 316Ti stainless for wood, oil, coal, or high-sulfur fuels, 304 where the fuel allows — because a flexible liner of the wrong alloy corrodes exactly as fast as any other.
The flexible liner is also the natural match for appliance venting, which is much of why this type exists. Dropping a liner from a gas or wood fireplace insert to the appliance collar almost always means negotiating the offset between the flue and the insert's outlet, and flexible makes that positive, full-length connection where rigid would bind — never a non-connected 'slammer.' Venting a stove or a high-efficiency appliance through an existing masonry chimney has the same geometry problem, and the flexible tube solves it. Because corrugation slightly slows draft and runs cooler, we add a liner-insulation wrap on solid-fuel and many appliance installs — it holds flue temperature up for draft, keeps creosote down, and maintains clearance to combustibles where the run passes near framing.
Installation is geometry-aware from top to bottom: we feed the liner from above, ease it through each offset rather than forcing it, insulate or pour-mix as required, and lock positive top-plate and appliance-collar connectors so the corrugated run is gas-tight end to end. Then we prove it — a smoke or draft check confirms the sealed path, and we document the UL-1777 listing for your records and any warranty, which on flexible liners is typically conditional on annual sweeping. How this differs from flue installation: that page often builds a brand-new, straight flue where a smooth clay or rigid run is the better first-time choice; flexible is the retrofit answer for an existing crooked flue rigid can't follow. And since one crew handles the scope, the liner, the appliance hookup, and the cap, a flexible-liner install is one tidy visit rather than a chain of separate specialists for each step.
With our crew, a flexible chimney liner installation is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the flexible chimney liner installation is built on.
Chimney inspectionA flexible chimney liner installation isn't a matter of opinion — it's held to published national standards. Texas Service builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
The flexible stainless liner we install is a UL-1777 listed lining system, certified for the application and documented for inspection. Its listing holds only when installed per the manufacturer's instructions, so that is how we run it.
Fuel decides the alloy: 316Ti stainless for wood, oil, coal, or high-sulfur fuels, and 304 where the fuel allows it. Put the flexible material in front of the wrong fuel and it corrodes early and voids the warranty.
Through offsets and elbows the flexible liner is eased, never forced, and always kept within the manufacturer's listed bend radius. That protects the corrugated wall from kinks and tears in the very spots a rigid liner could not pass at all.
For solid-fuel work and many appliance installs the flexible liner gets an insulation wrap. It holds flue temperature up for draft and preserves clearance to combustibles where the run passes near framing, 2 in interior masonry and 1 in exterior per the IRC.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Texas Service verifies them with your local authority having jurisdiction on every job.
We camera-map every offset, elbow, and pinch to confirm flexible is really needed, or whether rigid would do.
We match the diameter, round or oval, and the alloy to your appliance and fuel, then settle the insulation question.
The liner feeds down from above through the bends, gets insulated, and locks into positive top-plate and collar connectors.
A draft and smoke check plus UL-1777 documentation for your records and your warranty.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
Threads past offsets, elbows, and out-of-round tile that a rigid liner simply can't get through
The correct liner type for gas or wood inserts and for high-efficiency appliance venting
UL-1777 listed flexible stainless — transferable lifetime warranty
Insulated and oval-profile choices for flues that are tight, crooked, or running solid fuel
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

The NFPA recommends a Level 1 inspection every year, with a sweep once buildup reaches 1/8" of creosote — for a wood fireplace you actually use, that's about once a heating season. The neighborly part: since we're already on the roof, the same crew checks your dryer vent and caps the visit with a quick whole-home safety look, so one appointment covers what would otherwise be three.
Yes — our inspectors hold current CSIA (Chimney Safety Institute of America) certifications, verifiable in the CSIA member directory at csia.org, and we have NFI specialists for fireplace work. The same trained crew handles your chimney, fireplace, dryer-vent and air-duct needs, so you're not juggling four different contractors for one house.
Yes — 24/7 response (subject to crew availability) for active leaks, an animal trapped in the flue, post-fire damage, and storm damage, same-day in most cases. One call reaches one crew that can handle whatever the situation turns out to need, instead of bouncing you between specialists while the water's still coming in.
Always — a written quote before we lift a tool, with photos of what we found, so you see exactly what you're approving. If the same visit turns up something in the dryer vent or ducts, it goes on one itemized quote and one invoice rather than a string of separate trips.
The Whole-Home Care Plan is our annual maintenance plan at $19.99/month ($240/year): a Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency-response priority. Because one crew covers chimney, fireplace, dryer-vent and ducts, the plan keeps the whole house on a single schedule instead of a calendar full of separate service calls. Cancel anytime, no contract.
Last reviewed:
Other services in the Installation category.
Free written quote. Same-week scheduling. 24/7 emergency response when you need it.
Active leak, animal in flue, post-fire damage, or smoke event? Real humans on the line 7 AM to 12 AM every day — replies in under 2 minutes. Tech dispatch within 2 hours during business hours, subject to crew availability after-hours.
Emergency line